NUR 7110 Module 3 User-Centered Design Paper: A Postpartum Blood Pressure App Built With Patients Example

Reviewed by Gwyneth Ollerton, MSN, RN Thomas Edison State University Updated October 2026

User-centered design of a consumer health app is the subject of this NUR 7110 Module 3 sample paper, in which an invented Newark hospital builds a postpartum blood pressure check-in app with the mothers who will use it. Prepared for the consumer informatics course in TESU's MSN Nursing Informatics specialty, the paper uses Davis's technology acceptance model, which says people adopt a tool they believe is useful and easy, Brooke's ten-item System Usability Scale and an analysis of thousands of SUS results that gives scores a benchmark. Three rounds of testing, the changes each produced and a launch plan close this NUR-7110 paper.

CourseNUR-7110 Nursing Informatics Consumer Informatics and Communications Technologies
ModuleModule 3
Paper typeConsumer informatics paper: user-centered design and acceptance
LengthAbout 1,053 words, 6 pages
FormatAPA 7 student paper
SchoolThomas Edison State University
ProgramM.S. in Nursing, Nursing Informatics
UpdatedOctober 2026

Free sample paper for NUR 7110 Module 3

1

Designed by the Mothers Who Use It: A Postpartum Blood Pressure App Built Through Three Rounds of Testing in Newark

Student Name

M.S. in Nursing, Nursing Informatics, Thomas Edison State University

NUR-7110: Nursing Informatics: Consumer Informatics and Communications Technologies

Mentor Name

Month Day, Year

What this page is doingThe title credits the patients who shaped the app, because user-centered design means the design changes each time they say something does not work.
2

Designed by the Mothers Who Use It: A Postpartum Blood Pressure App Built Through Three Rounds of Testing in Newark

Why This App

The hospital and every participant in this example are invented. A hospital in Newark delivers about 3,600 babies a year, and many of its patients have high blood pressure during or after pregnancy. Dangerous blood pressure rises can happen in the days after discharge, when mothers are at home with a newborn and may not recognize warning signs. The hospital already sends some mothers home with a blood pressure cuff and asks them to call in readings, but few call. The obstetric nursing team proposed an app in which mothers enter readings and symptoms each day for two weeks, with nurses alerted when a reading or symptom needs action.

The informatics nurse was asked to lead the design. She insisted that mothers shape it from the first sketch.

Why People Use a Technology

Davis (1989) proposed the technology acceptance model to explain why some systems are taken up and others ignored. Perceived usefulness is how strongly someone expects the system to improve their work or life; perceived ease of use is how little effort they expect it to demand. Both beliefs tracked actual use in his studies, though usefulness tracked it more closely: people will put up with some difficulty for a tool that clearly helps them, but will not use an easy tool that does not. Ease of use worked partly by making a system seem more useful.

For postpartum mothers, the model suggested two design questions. Would mothers believe the app helps them and their baby, not only the hospital? And could a tired mother with a newborn use it in under a minute?

Measuring Usability

Brooke (1996) created the System Usability Scale as a quick, reliable way to measure perceived usability. It has ten statements, alternating positive and negative, rated on a five-point scale and combined into a score from 0 to 100. It was designed to be short enough to use after any test and general enough to compare different systems.

Bangor et al. (2008) analyzed a large collection of SUS results from many usability studies and found the scale reliable and sensitive across products and interfaces. Average scores across studies fell around 70, which gives designers a rough benchmark: a score well below that suggests serious problems, and a score in the 80s suggests a good experience.

Three Rounds

The first round changed the app's purpose in mothers' eyes. Mothers said that an app that only collected numbers felt like homework for the hospital. When each reading produced a plain message, such as "Your blood pressure is in a safe range today" or "This reading is high. A nurse will call you within an hour. If you have a severe headache, call 911," mothers described the app as something that would help them worry less. In the terms of Davis's model, perceived usefulness rose.

The second round found ease-of-use problems that the design team had not imagined. Mothers often held a baby in one arm, so small number fields were hard to tap. Spanish-speaking mothers wanted the whole app in Spanish, not only the instructions. A SUS score of 62 confirmed that the prototype was below the typical benchmark.

By the third round, with a large number pad, voice entry, full Spanish and reminders set at a time the mother chose, the SUS average rose to 81, and most mothers entered readings every day of the test week.

RoundWho and howMain findingsChanges made
1: Paper sketches8 mothers in postpartum clinic; talk-aloudWanted reassurance, not only instructions; symptoms list confusingAdded a message after each entry saying what the reading means
2: Clickable prototype10 mothers at home by video; SUSSUS average 62; entering numbers hard one-handed; Spanish neededLarge number pad, Spanish version, voice entry option
3: Working app12 mothers for one weekSUS average 81; most entered readings dailyReminder time chosen by the mother; nurse callback within an hour for red readings
What this page is doingEach round's findings change the next version. Mentors credit testing that shows how design evolved.
3

Behind the Screen

User-centered design extended to the nurses who receive alerts. Obstetric nurses tested the alert screen and asked that red readings appear on a single list with the mother's phone number and discharge summary, and that yellow readings go to a daily review rather than interrupting them. The hospital set a rule that red readings receive a call within an hour, every day of the week.

Equity in the Design

The informatics nurse recruited testers deliberately. Of the 30 mothers across the three rounds, more than half were Black or Hispanic, eleven had Medicaid and nine preferred Spanish, roughly matching the hospital's postpartum population with high blood pressure. Two testers had older phones with little storage, which revealed that the first build was too large to install. Without these testers, the team would have launched an app that worked well for mothers like its designers and poorly for the mothers at highest risk. The team also offered testers a gift card and paid for their data use, so that taking part did not cost them anything.

Launch Plan

Mothers with blood pressure problems during pregnancy or delivery will be offered the app and a cuff before discharge, with a nurse showing them how to take a reading and enter it. The app works on older phones and uses little data, and the hospital provides a loaner phone to mothers without one.

Measures

The hospital will track enrollment, daily entry rates, red readings and time to callback, emergency visits and readmissions for high blood pressure in the first two weeks and SUS scores at the end of the program.

Limits

Testing involved 30 mothers, and real use over two weeks may differ from a one-week test. The technology acceptance model explains intention to use but not every reason people stop. A high SUS score does not prove that the app improves health.

Conclusion

Mothers shaped an app that the hospital alone would have built differently. Davis's model explained why reassurance mattered as much as ease of entry, the SUS gave a quick measure in each round and a large body of SUS results provided a benchmark. Three rounds of testing moved the app from a score below average to one that mothers rated highly.

References

Bangor, A., Kortum, P. T., & Miller, J. T. (2008). An empirical evaluation of the System Usability Scale. International Journal of Human-Computer Interaction, 24(6), 574-594. https://doi.org/10.1080/10447310802205776

Brooke, J. (1996). SUS: A "quick and dirty" usability scale. In P. W. Jordan, B. Thomas, B. A. Weerdmeester, & I. L. McClelland (Eds.), Usability evaluation in industry (pp. 189-194). Taylor & Francis.

Davis, F. D. (1989). Perceived usefulness, perceived ease of use, and user acceptance of information technology. MIS Quarterly, 13(3), 319-340. https://doi.org/10.2307/249008

Reading the NUR 7110 Module 3 assignment instructions

Designing health information, services and support around the people who use them sits at the heart of TESU's catalog description of NUR-7110, and the syllabus is not published, so module three asks for a consumer health tool to be designed and tested. A paper of this kind explains why the tool is needed, uses a model of technology acceptance or a design framework, involves users from early sketches onward, tests in rounds with a standard usability measure, reports what changed after each round and plans launch and measurement. Some sections ask for a design proposal without testing. Check whether usability testing with real people is allowed in your setting, what approval it needs and whether a prototype image should be included. Describe who your testers were and how they match the people who will use the tool.

Inside the NUR 7110 Module 3 example

An invented Newark hospital's postpartum blood pressure problem and its unused call-in program open the paper. Davis's technology acceptance model frames usefulness and ease of use, and the System Usability Scale and a large analysis of SUS results give a way to measure. A three-row table follows the rounds of testing from paper sketches to a working app, with findings and changes. The text explains how reassurance raised usefulness and how one-handed entry and Spanish raised ease of use, with SUS rising from 62 to 81. Nurses' alert design, a launch plan, measures and limits precede the close. An annotation points to the design changing with each round, and a section on recruiting testers shows how the team avoided designing only for people like itself.

NUR 7110 Module 3 rubric: what earns full marks

Design papers earn credit for a clear need, accurate use of an acceptance model or design framework, user involvement from the start, testing in rounds with a standard measure, findings that visibly change the design and a launch plan with measures. Mentors notice when the writer designs for the person behind the clinical task, such as a mother holding a baby. Including the clinicians who receive the data shows a full view of the system. Reporting a low score honestly before improving it shows integrity. Sources, including a book chapter for the usability scale, should be cited correctly in APA style. Recruiting testers who match the people at highest risk shows equity in practice.

NUR 7110 Module 3 help from the desk

Design papers often describe a finished app and a single satisfaction survey; show how testing changed the design. Another frequent problem is designing only for patients who are like the design team. Use a recognized acceptance model to explain what will make people use the tool. Test with a standard measure such as the SUS and compare with a benchmark. Include the clinicians on the other end. Plan for patients without phones. A first draft of your own design paper, written to your brief, is free, and the Newark app shows how much detail to include.

Write yours, or have the desk draft it

This paper is an original model document written by our desk, not a submitted student paper and not an official Thomas Edison State University document. Read it for the moves, then write your own to the instructions in your classroom. If you want one built to your exact prompt and rubric, the first custom sample is free and arrives in 24 to 48 hours.

More NUR 7110 and M.S. in Nursing, Nursing Informatics sample papers

NUR 7110 Module 3 questions, answered

Where can I find a free NUR 7110 Module 3 sample paper?

The user-centered design paper for an invented Newark hospital's postpartum blood pressure app, from paper sketches to a working app, is printed here in full.

What is the technology acceptance model?

Davis's account of why people adopt a technology: they adopt it when they expect it to help and expect little effort, and the expectation of help counts for more.

What is the System Usability Scale?

A ten-item questionnaire Brooke built for quick usability checks, scored from 0 to 100.

What is a good SUS score?

Average scores across many studies fall around 70; scores in the 80s suggest a good experience.

Why test in rounds?

Each round reveals problems the designers did not anticipate, and the next version can fix them before launch.